Briggs & Stratton PowerProtect™ DX 22kW Home Standby Generator

Briggs & Stratton PowerProtect™ DX 22kW Home Standby Generator

$6,053.00

SPECIFICATIONS PPDX22 OVERVIEW

Brand Briggs & Stratton Series Name PowerProtect™ Model Name PPDX22

Power, Standby (LP/NG) (kW) 22

Rated AC Voltage (Volts)1 120 / 240

Rated Frequency (Hz)1 60

Generator Breaker (Amps) 100

Operating Ambient Temperature (°C/ °F) -28 to 40 / -20 to 104

Rated Amperage, Standby (LP/NG) (Amps)1 91.7 / 91.7

Rated Power Factor 1.0

Programmable Exercise Cycle 16 sec (default) - 20 mins

Engine Engine Brand/Manufacturer Vanguard Model Type M61

Aspiration Naturally Aspirated

Speed (RPM) 3600

Displacement (ci/cc) 61 / 993

Compression Ratio 9.7:1

Governor Type SAE J1444 Class B Frequency Regulation

Bore & Stroke (in/mm) 3.37 x 3.41 / 85.5 x 86.5

Cylinder Block Aluminum w Cast Iron Sleeve

Valve Arrangement OHV

Standby Generators PPDX22 Engine Engine Cylinder Configuration V Number of Cylinders 2

Start Type Automatic,

Starter Motor

Air Filter Type Dry

Low Oil Pressure Switch Yes

Engine Oil Heater Available as an Accessory Rated Temperature (°F/ °C) 77 / 25

Lubrication System Type Full Pressure

Oil Capacity (oz/L) 78 / 2.31

Oil Filter (Quantity/Type) 1 / Cartridge

Oil Brand Schaeffer Recommended Oil 5W30 Full Synthetic

Fuel System Fuel Type NG / LPV

Fuel Supply Line Inlet 3/4” NPT

Recommended Fuel, Lower Heating Value Minimum (MJ/m3 / BTU/ft3) NG: 34.3 / 904 LPV: 87.1 / 2338

Fuel Supply Pressure (mbar/in H20) NG: 9-17 / 3.5-7 LPV: 28-34 / 11-14

Standby Generators Sound Rating Low Idle Mode Sound dB(A)2 64 Normal Operating Sound dB(A)2 68

Battery Voltage (VDC) 12

Battery CCA (Amps) 540 Battery BCI Group Size 26 or 51

Starter Motor Voltage (VDC) 12

Fuel Consumption No Load, NG (BTU/hr) 107,000 No Load NG (ft3/hr) 107 Half Load, NG (BTU/hr) 194,000

RESIDENTIAL STANDBY GENERATORS SPECIFICATIONS

Fuel Consumption Half Load, NG (ft3/hr) 194 Full Load, NG (BTU/hr) 281,000 Full Load, NG (ft3/hr) 281 No Load, LP (BTU/hr) 108,000 No Load, LP (ft3/hr) 43 No Load, LP (gal/hr) 1.2 Half Load, LP (BTU/hr) 217,000 Half Load, LP (ft3/hr) 87 Half Load, LP (gal/hr) 2.4 Full Load, LP (BTU/hr) 368,000 Full Load, LP (ft3/hr) 147 Full Load, LP (gal/hr) 4.1

Alternator Specifications

Alternator Type Synchronous, Self-Excited, Rotating Field

Alternator Manufacturer B&S Rated Frequency (Hz)1 60

Rated Phase1

Insulation Rating (Class) H Designed Temperature Rise (°C) 125

Bearing (Quantity/Type) 1 / Sealed

Number of Poles 2

Voltage Regulator Brushed /

Electronic Motor Starting Capability (kVA) 45

Total Harmonic Distortion (THD), NL to FL (%) < 5

PPDX22 Controls /

Instrumentation Controller GC-1032

Charger

Stand Alone Starting AMF or 2-wire LED Display with Fault Code Indications Yes

Real Time Clock Yes

Engine Hour Counter Yes

Engine Runtime Scheduler Yes

Quantity:
Add To Cart